ROBOTIS H54-100-S500-RA
ROBOTIS H54-100-S500-RA: DYNAMIXEL serial-bus actuator. Open values held: position and velocity step (ROBOTIS dynamixel_hardware_interface); model number (ROBOTIS dynamixel-workbench), all under Apache-2.0. Torque, speed, voltage range, current and mass are not stated in these open files.
Specifications
| Attribute | Value | Conditions | Type | Source, read date, quote |
|---|---|---|---|---|
| Model number | 53769 | value the servo returns from its Model Number register; #define PRO_H54_100_S500_R_A in dynamixel_item.h | spec | github.com 2026-11-16“#define PRO_H54_100_S500_R_A 53769” |
| Resolution angle | 6.259112759506524e-06 rad = 0.02152 arcmin | radians per step of the Present Position register ([unit info] of h54_100_s500_ra.model); the file name ends '_ra' (PRO R(A) firmware; dynamixel_item.h names it ..._R_A) | spec | github.com 2026-11-16“Present Position 0.000006259112759506524 rad signed 0.0” |
| Velocity resolution | 0.0010471976 rad/s = 0.01 rpm | rad/s per step of the Present Velocity register ([unit info] of h54_100_s500_ra.model); the file name ends '_ra' (PRO R(A) firmware; dynamixel_item.h names it ..._R_A) | spec | github.com 2026-11-16“Present Velocity 0.0010471976 rad/s signed 0.0” |