| Nominal voltage | 48 V | column 115x25 of the 14-model table | spec | tq-group.com 2026-11-08“Rated voltage Ur* [V] 24 24 24 24 48 48 48 48 48 48 48 48 48 48” |
|---|
| Rated torque | 3.9 Nm | column 115x25 of the 14-model table; thermal behaviour depends on installation | spec | tq-group.com 2026-11-08“Rated torque T * [Nm] r 0.033 0.063 0.145 0.099 0.23 0.3 0.54 0.66 1.25 0.3 1.44 2.57 2.9 3.9” |
|---|
| Peak torque | 12.7 Nm | column 115x25 of the 14-model table; thermal behaviour depends on installation; at 20% deviation from linearity | spec | tq-group.com 2026-11-08“Peak torque Tmax at 20% deviation from 0.106 0.204 0.474 0.33 0.76 0.96 1.75 2.13 4.05 0.99 4.66 8.31 9.37 12.7” |
|---|
| Rated current | 14 A | column 115x25 of the 14-model table; star-serial interconnection; at nominal current, 20 C where stated; thermal behaviour depends on installation | spec | tq-group.com 2026-11-08“Rated current Ir* [A] 3.7 4.3 4.7 5.4 6.1 5.1 5.3 6.1 6.7 7.2 10.8 11.3 11.5 14.0” |
|---|
| Rated power | 570 W | column 115x25 of the 14-model table | spec | tq-group.com 2026-11-08“Power P [W] 77 89 95.7 110 248 209 219 250 277 284 443 465 470 570” |
|---|
| Mass | 1070 g | column 115x25 of the 14-model table | spec | tq-group.com 2026-11-08“Weight m [g] 16 25 54 53 89 87 135 220 330 210 400 620 670 1,070” |
|---|
| Length | 38.7 mm | column 115x25 of the 14-model table | spec | tq-group.com 2026-11-08“Length L [mm] 10.8 15.2 24.8 15.3 22.3 16.4 22.6 22.7 30.5 17.7 26.9 36.9 40.3 38.7” |
|---|
| Max speed | 2800 rpm | column 115x25 of the 14-model table; mechanical limit at rated voltage | spec | tq-group.com 2026-11-08“Max rotation speed 24,000*** 24,000*** 24,000*** 15,000*** 15,000*** 12,000*** 12,000*** 10,000*** 10,000*** 7,900*** 7,900*** 7,900*** 7,900*** 2,800***” |
|---|
| No-load speed | 1400 rpm | column 115x25 of the 14-model table; star-serial interconnection; at nominal current, 20 C where stated | spec | tq-group.com 2026-11-08“No load speed [rpm] 22,378 13,492 6,288 10,575 10,190 6,710 3,849 3,650 2,110 7,900** 2,938 1,728 1,560 1,400” |
|---|
| Outside dia. | 115 mm stated as diameter | column 115x25 of the 14-model table | spec | tq-group.com 2026-11-08“Diameter D [mm] 25 25 25 38 38 50 50 69 69 85 85 85 85 115” |
|---|
| Pole pairs | 15 pairs | column 115x25 of the 14-model table | spec | tq-group.com 2026-11-08“Number of pole pairs 7 7 7 7 7 10 10 10 10 10 10 10 10 15” |
|---|
| Terminal inductance | 600 μH | column 115x25 of the 14-model table; star-serial interconnection; at nominal current, 20 C where stated | spec | tq-group.com 2026-11-08“Terminal inductance 180 330 626 280 520 490 850 910 1,460 200 560 930 1,040 600” |
|---|
| Terminal resistance | 140 mΩ | column 115x25 of the 14-model table; star-serial interconnection; at nominal current, 20 C where stated | spec | tq-group.com 2026-11-08“Terminal resistance 530 740 1,240 350 490 540 770 470 660 140 220 300 320 140” |
|---|
| Torque constant | 281 mNm/A | column 115x25 of the 14-model table; star-serial interconnection; at nominal current, 20 C where stated | spec | tq-group.com 2026-11-08“Torque constant kT* 8.8 14.7 31.6 18.9 39 58 103 109 187 43 134 229 253 281” |
|---|