Parts › Connectors › Generic 12 AWG stranded copper hookup wire size-level table data
0 pickedCompare
Silicone wire 14 AWG (3.4 mm), red and black coils about 55 mm across
Wire: a picture of the part type, not this model. How it works

Generic 12 AWG stranded copper hookup wire size-level table data

Size-level record for 12 AWG copper hookup wire. It collects public wire tables; each table has its own conditions and they disagree.

Key specifications

Key specifications
Current rating25 A, 11.5 A, 13 A, 19 A and more 4 sources
Conductor area3.309 mm², 2.976 mm², 3.31 mm² 3 sources

· Maker or source page

Specifications

Specifications
AttributeValueConditionsTypeSource, read date, quote
Current rating13 amps stated as ampacityFAA AC 43.13-1B Table 11-9, continuous duty in bundles, 105 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitudespecraanz.org.nz 2026-11-08“12 13 19 25 2.02 5,874”
19 amps stated as ampacityFAA AC 43.13-1B Table 11-9, continuous duty in bundles, 150 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitudespecraanz.org.nz 2026-11-08“12 13 19 25 2.02 5,874”
25 amps stated as ampacityFAA AC 43.13-1B Table 11-9, continuous duty in bundles, 200 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitudespecraanz.org.nz 2026-11-08“12 13 19 25 2.02 5,874”
11.5 A stated as ampacityNASA EEE-INST-002 Table 4A derated current, bundled wire or multi-conductor cable; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wirespecnepp.nasa.gov 2026-11-08“12 25.0 11.5”
25.0 A stated as ampacityNASA EEE-INST-002 Table 4A derated current, single wire; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wirespecnepp.nasa.gov 2026-11-08“12 25.0 11.5”
41 A stated as ampacityPowerStream guideline, maximum amps for chassis wiring, meant for wiring in air and not in a bundle; the site calls it a rule of thumbclaimpowerstream.com 2026-11-09“12 0.0808 2.05232 3.31 1.588 5.20864 41 9.3”
9.3 A stated as ampacityPowerStream guideline, maximum amps for power transmission, uses 700 circular mils per amp, which the site calls very conservativeclaimpowerstream.com 2026-11-09“12 0.0808 2.05232 3.31 1.588 5.20864 41 9.3”
20 A stated as ampacityWikipedia AWG table, 60 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinnerclaimen.wikipedia.org 2026-11-09“12 0.0808 2.053 12.4 4.87 6.53 3.31 5.211 1.588 20 25 30”
25 A stated as ampacityWikipedia AWG table, 75 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinnerclaimen.wikipedia.org 2026-11-09“12 0.0808 2.053 12.4 4.87 6.53 3.31 5.211 1.588 20 25 30”
30 A stated as ampacityWikipedia AWG table, 90 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinnerclaimen.wikipedia.org 2026-11-09“12 0.0808 2.053 12.4 4.87 6.53 3.31 5.211 1.588 20 25 30”
Conductor area5874 circ.mils = 2.976 mm²FAA AC 43.13-1B Table 11-9, nominal conductor areaspecraanz.org.nz 2026-11-08“12 13 19 25 2.02 5,874”
6530 circular mils = 3.309 mm²NIST Handbook 100 Table 5, standard annealed copper, solid round AWG size; a stranded wire's area differsspecnvlpubs.nist.gov 2026-11-09“12 80.8 6530 .005 13 1.59”
3.31 mm2Wikipedia AWG table, solid round conductorclaimen.wikipedia.org 2026-11-09“12 0.0808 2.053 12.4 4.87 6.53 3.31 5.211 1.588 20 25 30”
Resistance per length2.02 ohms/1000ftFAA AC 43.13-1B Table 11-9, maximum at 20 C, tin plated conductorspecraanz.org.nz 2026-11-08“12 13 19 25 2.02 5,874”
1.59 ohms per 1,000 feetNIST Handbook 100 Table 5, standard annealed copper at 20 C, solid round AWG sizespecnvlpubs.nist.gov 2026-11-09“12 80.8 6530 .005 13 1.59”
5.211 mOhm/mWikipedia AWG table, solid copper wire at 68 F (20 C), computed based on 100% IACS conductivityReview note: Capture never says annealed; note [7] gives solid copper at 68 F (20 C) and 100% IACS, so the temperature condition is lost.claimen.wikipedia.org 2026-11-09“12 0.0808 2.053 12.4 4.87 6.53 3.31 5.211 1.588 20 25 30”