| Current rating | 4 amps stated as ampacity | FAA AC 43.13-1B Table 11-9, continuous duty in bundles, 105 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitude | spec | raanz.org.nz 2026-11-08“20 4 7 9 9.88 1,216” |
|---|
| 7 amps stated as ampacity | FAA AC 43.13-1B Table 11-9, continuous duty in bundles, 150 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitude | spec | raanz.org.nz 2026-11-08“20 4 7 9 9.88 1,216” |
| 9 amps stated as ampacity | FAA AC 43.13-1B Table 11-9, continuous duty in bundles, 200 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitude | spec | raanz.org.nz 2026-11-08“20 4 7 9 9.88 1,216” |
| 3.7 A stated as ampacity | NASA EEE-INST-002 Table 4A derated current, bundled wire or multi-conductor cable; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wire | spec | nepp.nasa.gov 2026-11-08“20 6.5 3.7” |
| 6.5 A stated as ampacity | NASA EEE-INST-002 Table 4A derated current, single wire; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wire | spec | nepp.nasa.gov 2026-11-08“20 6.5 3.7” |
| 11 A stated as ampacity | PowerStream guideline, maximum amps for chassis wiring, meant for wiring in air and not in a bundle; the site calls it a rule of thumb | claim | powerstream.com 2026-11-09“20 0.032 0.8128 0.519 10.15 33.292 11 1.5” |
| 1.5 A stated as ampacity | PowerStream guideline, maximum amps for power transmission, uses 700 circular mils per amp, which the site calls very conservative | claim | powerstream.com 2026-11-09“20 0.032 0.8128 0.519 10.15 33.292 11 1.5” |
| 5 A stated as ampacity | Wikipedia AWG table, 60 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinner | claim | en.wikipedia.org 2026-11-09“20 0.0320 0.812 31.3 12.3 1.02 0.518 33.31 10.15 5 11 —” |
| 11 A stated as ampacity | Wikipedia AWG table, 75 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinner | claim | en.wikipedia.org 2026-11-09“20 0.0320 0.812 31.3 12.3 1.02 0.518 33.31 10.15 5 11 —” |
| Conductor area | 1216 circ.mils = 0.6162 mm² | FAA AC 43.13-1B Table 11-9, nominal conductor area | spec | raanz.org.nz 2026-11-08“20 4 7 9 9.88 1,216” |
|---|
| 1020 circular mils = 0.5168 mm² | NIST Handbook 100 Table 5, standard annealed copper, solid round AWG size; a stranded wire's area differs | spec | nvlpubs.nist.gov 2026-11-09“20 32.0 1020 .000 804 10.1” |
| 0.518 mm2 | Wikipedia AWG table, solid round conductor | claim | en.wikipedia.org 2026-11-09“20 0.0320 0.812 31.3 12.3 1.02 0.518 33.31 10.15 5 11 —” |
| Resistance per length | 9.88 ohms/1000ft | FAA AC 43.13-1B Table 11-9, maximum at 20 C, tin plated conductor | spec | raanz.org.nz 2026-11-08“20 4 7 9 9.88 1,216” |
|---|
| 10.1 ohms per 1,000 feet | NIST Handbook 100 Table 5, standard annealed copper at 20 C, solid round AWG size | spec | nvlpubs.nist.gov 2026-11-09“20 32.0 1020 .000 804 10.1” |
| 33.31 mOhm/m | Wikipedia AWG table, solid copper wire at 68 F (20 C), computed based on 100% IACS conductivityReview note: Capture never says annealed; note [7] gives solid copper at 68 F (20 C) and 100% IACS, so the temperature condition is lost. | claim | en.wikipedia.org 2026-11-09“20 0.0320 0.812 31.3 12.3 1.02 0.518 33.31 10.15 5 11 —” |