| Current rating | 3 amps stated as ampacity | FAA AC 43.13-1B Table 11-9, continuous duty in bundles, 105 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitude | spec | raanz.org.nz 2026-11-08“22 3 5 6 16.20 755” |
|---|
| 5 amps stated as ampacity | FAA AC 43.13-1B Table 11-9, continuous duty in bundles, 150 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitude | spec | raanz.org.nz 2026-11-08“22 3 5 6 16.20 755” |
| 6 amps stated as ampacity | FAA AC 43.13-1B Table 11-9, continuous duty in bundles, 200 C conductor rating; 70 C ambient, 33 or more wires in the bundle, no more than 20 percent of harness capacity used, 60,000 ft altitude | spec | raanz.org.nz 2026-11-08“22 3 5 6 16.20 755” |
| 2.5 A stated as ampacity | NASA EEE-INST-002 Table 4A derated current, bundled wire or multi-conductor cable; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wire | spec | nepp.nasa.gov 2026-11-08“22 4.5 2.5” |
| 4.5 A stated as ampacity | NASA EEE-INST-002 Table 4A derated current, single wire; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wire | spec | nepp.nasa.gov 2026-11-08“22 4.5 2.5” |
| 7 A stated as ampacity | PowerStream guideline, maximum amps for chassis wiring, meant for wiring in air and not in a bundle; the site calls it a rule of thumb | claim | powerstream.com 2026-11-09“22 0.0253 0.64516 0.327 16.14 52.9392 7 0.92” |
| 0.92 A stated as ampacity | PowerStream guideline, maximum amps for power transmission, uses 700 circular mils per amp, which the site calls very conservative | claim | powerstream.com 2026-11-09“22 0.0253 0.64516 0.327 16.14 52.9392 7 0.92” |
| 3 A stated as ampacity | Wikipedia AWG table, 60 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinner | claim | en.wikipedia.org 2026-11-09“22 0.0253 0.644 39.5 15.5 0.642 0.326 52.96 16.14 3 7 —” |
| 7 A stated as ampacity | Wikipedia AWG table, 75 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinner | claim | en.wikipedia.org 2026-11-09“22 0.0253 0.644 39.5 15.5 0.642 0.326 52.96 16.14 3 7 —” |
| Conductor area | 755 circ.mils = 0.3826 mm² | FAA AC 43.13-1B Table 11-9, nominal conductor area | spec | raanz.org.nz 2026-11-08“22 3 5 6 16.20 755” |
|---|
| 640 circular mils = 0.3243 mm² | NIST Handbook 100 Table 5, standard annealed copper, solid round AWG size; a stranded wire's area differs | spec | nvlpubs.nist.gov 2026-11-09“22 25.3 640 .000 503 16.2” |
| 0.326 mm2 | Wikipedia AWG table, solid round conductor | claim | en.wikipedia.org 2026-11-09“22 0.0253 0.644 39.5 15.5 0.642 0.326 52.96 16.14 3 7 —” |
| Resistance per length | 16.2 ohms/1000ft | FAA AC 43.13-1B Table 11-9, maximum at 20 C, tin plated conductor | spec | raanz.org.nz 2026-11-08“22 3 5 6 16.20 755” |
|---|
| 16.2 ohms per 1,000 feet | NIST Handbook 100 Table 5, standard annealed copper at 20 C, solid round AWG size | spec | nvlpubs.nist.gov 2026-11-09“22 25.3 640 .000 503 16.2” |
| 52.96 mOhm/m | Wikipedia AWG table, solid copper wire at 20 C, 100% IACS conductivityReview note: Temperature and solid-wire basis are lost: the table's footnote 7 says solid copper at 20 C and 100% IACS; the word annealed is not in the capture. | claim | en.wikipedia.org 2026-11-09“22 0.0253 0.644 39.5 15.5 0.642 0.326 52.96 16.14 3 7 —” |