Parts › Connectors › Generic 26 AWG stranded copper hookup wire size-level table data
0 pickedCompare
Silicone wire 14 AWG (3.4 mm), red and black coils about 55 mm across
Wire: a picture of the part type, not this model. How it works

Generic 26 AWG stranded copper hookup wire size-level table data

Size-level record for 26 AWG copper hookup wire. It collects public wire tables; each table has its own conditions and they disagree.

Key specifications

Key specifications
Current rating2.5 A, 1.4 A, 1.3 A, 2.2 A and more 3 sources
Conductor area0.1282 mm², 0.129 mm² 2 sources

· Maker or source page

Specifications

Specifications
AttributeValueConditionsTypeSource, read date, quote
Current rating1.4 A stated as ampacityNASA EEE-INST-002 Table 4A derated current, bundled wire or multi-conductor cable; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wirespecnepp.nasa.gov 2026-11-08“26 2.5 1.4”
2.5 A stated as ampacityNASA EEE-INST-002 Table 4A derated current, single wire; ambient 70 C or less, hard vacuum 1E-6 torr, 200 C rated wire such as PTFE; use 80 percent for 150 C wire and 70 percent for 135 C wirespecnepp.nasa.gov 2026-11-08“26 2.5 1.4”
2.2 A stated as ampacityPowerStream guideline, maximum amps for chassis wiring, meant for wiring in air and not in a bundle; the site calls it a rule of thumbclaimpowerstream.com 2026-11-09“26 0.0159 0.40386 0.128 40.81 133.8568 2.2 0.361”
0.361 A stated as ampacityPowerStream guideline, maximum amps for power transmission, uses 700 circular mils per amp, which the site calls very conservativeclaimpowerstream.com 2026-11-09“26 0.0159 0.40386 0.128 40.81 133.8568 2.2 0.361”
1.3 A stated as ampacityWikipedia AWG table, 60 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinnerclaimen.wikipedia.org 2026-11-09“26 0.0159 0.405 62.7 24.7 0.254 0.129 133.9 40.81 1.3 2.2 —”
2.2 A stated as ampacityWikipedia AWG table, 75 C insulation column; enclosed wire at 30 C ambient, or single unbundled wires in equipment for 16 AWG and thinnerclaimen.wikipedia.org 2026-11-09“26 0.0159 0.405 62.7 24.7 0.254 0.129 133.9 40.81 1.3 2.2 —”
Conductor area253 circular mils = 0.1282 mm²NIST Handbook 100 Table 5, standard annealed copper, solid round AWG size; a stranded wire's area differsspecnvlpubs.nist.gov 2026-11-09“26 15.9 253 .000 199 41.0”
0.129 mm2Wikipedia AWG table, solid round conductorclaimen.wikipedia.org 2026-11-09“26 0.0159 0.405 62.7 24.7 0.254 0.129 133.9 40.81 1.3 2.2 —”
Resistance per length41.0 ohms per 1,000 feetNIST Handbook 100 Table 5, standard annealed copper at 20 C, solid round AWG sizespecnvlpubs.nist.gov 2026-11-09“26 15.9 253 .000 199 41.0”
133.9 mOhm/mWikipedia AWG table, solid copper wire at 20 C, 100% IACS conductivityReview note: Temperature and solid-wire basis are lost: the table's footnote 7 says solid copper at 20 C and 100% IACS; the word annealed is not in the capture.claimen.wikipedia.org 2026-11-09“26 0.0159 0.405 62.7 24.7 0.254 0.129 133.9 40.81 1.3 2.2 —”