Design Book › Electrical and power

Electrical and power

Budget power before you choose a motor, since supply limits can set the peak current [1], [2]. For the robot's power tree, a designer must do these.

  1. Sum continuous and peak joint power. Hold continuous load near 80 percent of source capacity when no monitoring is used [3].
  2. Size each wire for both voltage drop and heat [4].
  3. Protect every power wire near the source [5], so the protector opens first [6].
  4. Size the battery for both capacity and current, within the voltage limits [7]. Lower temperature reduces Li-ion capacity and steepens the discharge curve, so check the coldest use [8].
  5. Count voltage drop in the torque budget [9].
  6. Pick a bus that meets your timing, then follow its length and termination guidelines.

Most electrical guidelines come from an FAA aircraft advisory circular and a NASA flight parts document. They are aircraft and flight rules, used here as the public guidance available. Scope is on each guideline.

Wire

The guideline tables below give current in amps per wire. Wire parts and more sizes follow them, under Wire parts. Wire parts have no price rows in this edition.

Wire
Size, AWGFAA bundled, 105 C ratingFAA bundled, 150 CFAA bundled, 200 CNASA singleNASA bundledSources
242.5453.32.0[10], [11]
204796.53.7[12], [13]
167111413.06.5[14], [15]
1213192525.011.5[16], [17]

Conditions differ, so the columns are not comparable. FAA values for sizes 24 through 10 assume 70 C ambient, 60,000 ft altitude, a bundle of 33 or more wires, and no more than 20 percent harness loading [18]. NASA values assume 70 C ambient or less, hard vacuum and 200 C wire [11]. Scale NASA values to 80 percent for 150 C wire and 70 percent for 135 C wire [19].

Wire
LevelStatementCheckSource
shouldDo not exceed the current that heats a wire to its rated temperature at steady state.calc: T_ambient + wire self-heating <= wire rating[20]
mustDo not use wire with fewer than 19 strands.review: wire spec strand count >= 19[21]
shouldGive wire under size 20 extra clamps and support, and keep it out of excessive vibration, repeated bending, or frequent disconnection.review: harness routes for wire thinner than 20 AWG[22]
shouldKeep wire-group bend radius at least 10 times the largest wire or cable diameter, except supported terminal breakouts may use 3 times.model-lint: harness bend radius >= 10 * OD[23]
shouldFAA allowable drop bus to load is 0.5 V continuous and 1 V intermittent at 14 V, and 1 V and 2 V at 28 V.calc: I * R_wire(hot, both ways) <= allowable drop[24]
shouldKeep source-to-main-bus drop within 2 percent of regulated voltage at generator rated current or battery five-minute discharge rate.calc: V_drop_main <= 0.02 * V_bus[25]
mustSize each wire for both voltage drop and overheating; both must be met.calc: wire passes the drop check and the heat check[4]

The strand and bend guidelines are for static aircraft wire [22], [23]. A wire that crosses a joint needs a flex-rated cable and a test. Include harness force in the torque budget [26]. Route cables so they cannot snag [27].

Wire parts

The connector category holds wire: ten size-level records and 44 products. Four of the products show their values on this site. The other 40 come from maker sheets whose source does not let us show the values. No wire part has a price row in this edition. Values keep the source unit, as part pages do.

The size-level records collect public tables. They carry the word stranded in the name, but the NIST and Wikipedia rows are for solid round wire, and a stranded wire's area differs. The FAA rows are nominal area and maximum resistance for tin plated conductor.

Wire parts
AWGArea, NIST, circular milsArea, FAA, circular milsArea, Wikipedia, mm2Resistance at 20 C, NIST, ohm per 1000 ftResistance at 20 C, FAA, ohm per 1000 ftResistance at 20 C, Wikipedia, milliohm per m
12653058743.311.592.025.211
14411038312.082.523.068.286
16258024261.314.024.8113.17
18162019000.8236.396.2320.95
20102012160.51810.19.8833.31
226407550.32616.216.252.96
244044750.20525.728.484.22
26253not listed0.12941not listed133.9
28159not listed0.08165.3not listed212.9
30100not listed0.0509104not listed338.6

Ampacity tables disagree. Values are amps per wire, each under its own conditions. Do not read one column as the true limit. The database does not pick a winner.

Wire parts
AWGFAA bundled, 105 / 150 / 200 CNASA single / bundledWikipedia, 60 / 75 / 90 CPowerStream chassis / power transmission
1213 / 19 / 2525 / 11.520 / 25 / 3041 / 9.3
1410 / 14 / 1819 / 8.515 / 20 / 2532 / 5.9
167 / 11 / 1413 / 6.512 / 16 / 1822 / 3.7
186 / 9 / 129.2 / 510 / 14 / 1616 / 2.3
204 / 7 / 96.5 / 3.75 / 11 / not listed11 / 1.5
223 / 5 / 64.5 / 2.53 / 7 / not listed7 / 0.92
242.5 / 4 / 53.3 / 22.1 / 3.5 / not listed3.5 / 0.577
26not listed2.5 / 1.41.3 / 2.2 / not listed2.2 / 0.361
28not listed1.8 / 10.83 / 1.4 / not listed1.4 / 0.226
30not listed1.3 / 0.70.52 / 0.86 / not listed0.86 / 0.142

At 20 AWG the rows run from 1.5 A to 11 A. None of these tables is for a harness that crosses a moving joint. Choose by the conditions nearest your harness, then check heat and drop both [4].

Sellers give their own current figures. Adafruit 1884 and Adafruit 2520 list 3.5 A and 123 ohm/km at 26 AWG. That current is above every table row for that size. Adafruit 2051 lists 0.8 A and 331 ohm/km at 30 AWG. Adafruit says the figure depends on length, and on voltage as well for 2051. Keeppower lists 5 A and 0.5 mm2 at 20 AWG. None of them gives an ambient or a temperature rise.

Check the stranding too. The strand-count guideline asks for 19 strands or more, for aircraft wire [21]. Keeppower lists 100 strands of 0.08 mm at 20 AWG. Not every hookup wire meets the guideline, so read the stranding on the sheet of the wire you buy.

Protection, switches and derating

Protection, switches and derating
LevelStatementCheckSource
mustProtect every power wire with a fuse or breaker located as close as possible to the source bus.review: each power branch has a protection device near the bus[5]
mustMake the circuit protector open before anything downstream overheats or smokes.calc: protector curve is below wire and load damage curves[6]
mustSize wire to carry continuous current above the protector rating, including its time-current curve.calc: wire continuous ampacity > protector rating[28]
shouldDerate a switch nominal rating by factor 3 for 28 VDC motor loads.calc: switch rating >= factor * motor current[29]
shouldDerate a switch nominal rating by factor 2 for 12 VDC motor loads.calc: switch rating >= 2 * motor current[30]
guideAircraft warning lights can be triggered when battery bus voltage falls below 13 V on a 14 V system or 26 V on a 28 V system.measure: under-voltage warning threshold on the main bus[31]

Derate power parts. The factors below are from NASA flight parts, and they are stricter than commercial practice.

Protection, switches and derating
PartLimitSource
MOSFET gate-source voltage0.60 of rating[32]
MOSFET source-drain voltage, with worst-case transients0.75 of rating[33]
MOSFET junction125 C, or 40 C below maximum, whichever is lower; or 0.80 of maximum[34], [35]
Connector working voltageLower of 25 percent of dielectric test voltage and 75 percent of rated[36]
Connector temperatureRated maximum minus 25 C[37]
Contact currentThe Table 4A wire derating value for the conductor size; on printed-circuit connectors, the bundled wire value for that contact size[38]

The motor driver category holds gate drivers and driver ICs, and the MOSFET category holds MOSFETs. Gate driver and MOSFET prices are not shown: the database holds them, but their sources do not let us copy them.

Grounding and noise

Grounding and noise
LevelStatementCheckSource
shouldGive each interface circuit a dedicated return wire close to its outgoing wire.review: every power and signal pair in the harness has its own return[39]
shouldAvoid shared return wires between circuits; this may be tolerable within one system component that provides its own box-to-box wiring.review: no shared returns between motor and signal circuits[40]
guideKeep a ground wire shorter than one twentieth of a wavelength.calc: L_ground < lambda / 20 at the highest noise frequency[41]
mustProvide electrical bonding and ground paths between moving and stationary parts to meet electromagnetic requirements.measure: bonding resistance across each joint[42]
mustFor NASA mechanisms, bearings shall not carry electrical current; provide other current paths and bonding/ground paths between moving and stationary parts.review: moving joints have a slip ring or flexible bond strap[43]
mustDo not carry electrical current through gears.review: no gear in a ground or signal path[44]

Motor return currents raise ground offsets, and that offset can push a bus out of its common-mode range [45]. Run a dedicated return for each circuit [39].

Batteries

Cells

Pick a cell by current first, then capacity. Two cells of one format and near one capacity can differ several times over in continuous current: an energy cell gives up current for capacity, and a power cell does the reverse. Ratings also differ by test method: some are quoted with a temperature cut-off and some without, so read the condition. See the battery cell category.

The table gives each format's size and typical capacity, from Wikipedia. Capacity is a range over many cells and is marked claim. These rows hold no current rating.

Cells
FormatDiameter x lengthTypical capacity
1865018 x 65 mm500 to 4050 mAh
2170021 x 70 mm2000 to 6500 mAh
2665026 x 65 mm3500 to 7000 mAh
3270032 x 70 mm7000 mAh
468046 x 80 mm23000 mAh

The database also holds named cells with capacity, continuous current, mass and price, such as Samsung 25R, Molicel P28A, Samsung 50E, Molicel P50B and the EVE LF314 LFP prismatic cell. Their rows come from a retail page and maker sheets that do not let us show the values. Open the maker sheet before you commit.

Cells
Chemistry or formatChoose it forCosts
Cylindrical 18650, 21700Default for robot packs: mature supply, rigid canNeeds welding or holders; energy cells cannot supply peaks
Pouch or LiPoFlexible shape, low mass, high discharge optionsSwelling and puncture risk; needs compression and protection
LFPCycle life (2,500 to 9,000 cycles per Wikipedia), safer chemistryHeavier per Wh; weak in the cold; flat curve hides state of charge

Ready-made LiPo packs run 400 / 4800 / 41000 mAh, 2 / 5 / 24 cells in series, and 7.4 / 18.7 / 91.2 V, at $12.19 / $112.49 / $2941.64. Quoted C rates run 5 / 60 / 160. These are seller claims, so test before you rely on a high C rating. Rates are commonly expressed as multiples of C rate, the current that discharges the battery to cutoff in one hour [46]. One example is Gens ace 5500 mAh 6S 60C, listed at 22.2 V and $160.99. Packs have strict charge and storage guidelines, and carry swelling and fire risk if abused.

Battery guidelines

Estimate sag with V_sag = I_peak * n_series * R_cell / n_parallel. Internal resistance ranges from 9 to 120 milliohm on small 1 to 3 Ah Li-ion cells [47]. A cell discharged at a high rate to cutoff still has capacity left if discharge continues at a lower rate [48]. Use the cell's rate curve, not its rated capacity. Most Li-ion cells work best between 20 and 40 C [49], and high-rate discharge can raise them far above ambient [50].

Battery guidelines
LimitValueSource
Discharge floor2.5 V per cell; typical equipment stops at 3.0 V[51]
Charge, typical layered-cathode Li-ionConstant current up to 3.9 V to 4.2 V, by cathode and maker[52]
Charge taper, typical layered-cathode Li-ionHold voltage until about C/50 or C/100, as the maker specifies[53]
Lot screen, open circuit spreadAfter removing outliers, 3-sigma range under 1 percent of mean[54]
Lot screen, capacity and massAfter removing outliers, 3-sigma range under 5 percent and 2 percent of mean[55]
Lot screen, DC and AC resistanceAfter removing outliers, 3-sigma range under 15 percent of mean[56]
Acceptance cyclesAt least 10 in total, counting vendor, screening, subassembly and completed-assembly cycles[57]
Transport testUN 38.3[58]
Shipping under 49 CFR 173.185(c)Generally 20 Wh per cell, 100 Wh per battery; 60 Wh and 300 Wh if marked highway or rail only[59]

Shipping limits bite early. Take a 3000 mAh cell at the 3.6 V nominal Li-ion voltage: it holds 10.8 Wh. That is under the 20 Wh cell limit, but ten of them pass the general 100 Wh battery limit [59].

Battery guidelines
LevelStatementCheckSource
mustDo not charge a Li-ion cell above the vendor's recommended voltage; overcharge can cause internal shorts, venting and flames.measure: cell voltage at end of charge <= vendor maximum[60]
mustUse a dedicated Li-ion charger or a universal smart charger that recognizes the battery chemistry. Final testing should treat battery and charger as one unit.measure: charger and pack tested as one system[61]
mustFit charge control to prevent overcharge, which can cause venting or rupture.review: charge control hardware present and independent of the main controller[62]
mustIn a series string control voltage so the lowest cell is not driven into reversal, which can cause venting or rupture.measure: per-cell undervoltage cutoff in series packs[63]
mustFor NASA crewed spacecraft, the battery/charger design shall maintain required failure tolerance against overcharge and over-discharge.review: hazard table with independent protection layers[64]
mustKeep operation inside limits recommended by the maker or found in qualification testing.review: BMS limits from maker data[65]
shouldFor NASA batteries above 80 Wh using cells above 80 Wh/kg with catastrophic failure modes, evaluate worst-case single-cell thermal runaway severity and cell-to-cell propagation in the intended application and environment.measure: propagation test or analysis for the pack design[66]
mustDo not pot cells in a way that blocks their vents.review: pack drawing shows vent path open[67]
mustExcept for cells or batteries meeting 49 CFR 173.185(c), a lithium battery with cells or series strings in parallel must have a means to prevent dangerous reverse current, such as diodes or fuses.review: parallel strings have fuses or diodes[68]
mustExcept for cells or batteries meeting 49 CFR 173.185(c), each lithium cell or battery must have a means of preventing external short circuits.review: short protection in pack and packaging[69]
mustAddress external shorts at pack level if cells lack current interrupt devices; fuses, breakers and thermal switches can be used.review: pack-level fuse or breaker; measure: short test on a sample[70]
shouldDo not rely on cell PTC devices in series or parallel/series strings, as they may not protect as they do in single cells.review: pack protection does not rely on PTC alone[71]
shouldFind the maximum number of cells in series without a bypass diode by test.measure: series string abuse test results[72]
shouldAnodize inner metal battery-case surfaces or coat them with non-electrically conductive, electrolyte-resistant paint to prevent electrolyte shorts.review: inner case surface finish[73]
shouldCycling can unbalance cells; long-cycle-life or low-margin applications are more likely to require cell monitoring and end-of-charge or discharge control.review: BMS has per-cell monitoring where margin is small[74]

Battery management

A BMS monitors cell voltage, current and temperature, balances cells, and cuts the pack off at its limits. The chip fixes the series count: BQ76920 to 5 cells and BQ76952 to 16. foxBMS 2 is an open platform. See the BMS category. A BMS needs its own firmware and safety case, and it adds a series MOSFET voltage drop. Prices of BMS boards, smart BMS units and fuel gauges are not shown: the database holds them, but their sources do not let us copy them. The BQ chips and foxBMS 2 have no price row.

Connectors

The data below are ratings. Derate them with the guidelines above. See the connector category. The Anderson and JST rows come from Wikipedia tables.

Connectors
ConnectorRated currentVoltageKind
Powerpole15/30/45 Anot listedclaim
Anderson SBS50, 75 or 110 A600 Vspec
Anderson SB / Multipole50 to 500 A across the series600 Vspec
JST GH1 A50 Vspec
JST SH1 A50 Vspec
JST PH2 A100 Vspec
JST XH3 A250 Vspec
JST SM3 A250 Vspec

The database also holds the Amass XT30U-M, XT60-F, XT60H-M and XT90H-M. Their ratings come from a source that does not let us show them, so read the maker sheet.

Wire-to-board connectors in the bulk table run from 0.8 to 7.92 mm in pitch, with a median of 2.5 mm. Their current ratings, voltage ratings and prices are not shown, and neither are housing prices. The database holds them, but their sources do not let us copy them.

Power conversion

Power conversion
ClassUseCosts
BuckStep battery down to 5 V, 12 V or logicOutput below input; switching noise; heat limits current
Buck-boostHold a rail above or below the inputInput current rises as voltage falls
IsolatedBreak the ground path between domainsLower efficiency; larger; extra noise

The category also holds DC-DC converter chips and LDO regulators. Most converter prices are not shown: the database holds them, but their sources do not let us copy them.

Parts: D36V50F5 and LM5164 for buck, S13V30F5 and TPS63020 for buck-boost, RSD-100B-24 for isolated.

Buses

Buses
BusChoose it forMain limitsSources
TTL serialBus servos on one wire, cheapShort cables, no differential noise immunity; bus loading limits servo countTTL serial bus
RS-485Long runs, many nodes, simple UARTNo arbitration; no standard connector or protocol[75]; more under RS-485 below
CAN 2.0Motor drives and BMS, hardware arbitration8-byte payload; 1 Mbit/s ceiling; rate falls with length[76]; more under CAN length against rate below
CAN FD64-byte payload, faster telemetry per jointFaster phase shortens allowed length; mixed networks need FD-tolerant nodesnone in this edition
EtherCATShort cycles, low jitter, many drives on one cableNeeds a slave chip per node and a real-time master[77]; more under EtherCAT below
EthernetCameras, lidar, computersNot deterministic without TSN or EtherCAT-style schedulesnone in this edition
USBCameras, adapters, programmingHost-polled; about 5 m on USB 2.0; connector retention in vibrationNo bus guideline; cable and latency notes [78], [79]

Adapter chips include CAN transceivers, isolated CAN transceivers, RS-485 and isolated RS-485 transceivers, and Ethernet PHYs. The LAN9252 and ET1100 are EtherCAT slave controllers. A TTL servo adapter such as Waveshare Adapter A joins a servo bus to a computer. Adapter prices are not shown: the database holds them, but their sources do not let us copy them.

CAN length against rate

CAN length against rate
Bit rateBeckhoffISO 11898 as reported by NISource
1 Mbit/sunder 20 m40 m total, 0.3 m stub[76], [80]
500 kbit/sunder 100 mnot listed[76]
250 kbit/sunder 250 mnot listed[76]
125 kbit/sunder 500 mnot listed[76]
50 kbit/sunder 1000 mnot listed[76]

Signal transit time sets the limit [81]. Use cable with a nominal line delay of 5 ns/m [82]. The Beckhoff and NI lengths differ [76], [80]. Use the shorter unless your own timing calculation supports more. Opto-isolated nodes can be shorter: Beckhoff's worst-case calculation gives 5 m at 1 Mbit/s, while it says 20 m can be reached in practice without difficulty [83].

CAN length against rate
LevelStatementCheckSource
guideIn CAN 2.0 bit-stuffed frame segments, a transmitter inserts a complementary bit after five consecutive identical bits.calc: bus load uses worst-case stuffed frame length[84]
guideCAN 2.0 defines SYNC_SEG as 1 time quantum and PROP_SEG and PHASE_SEG1 as programmable from 1 to 8 time quanta.calc: bit timing register values within CAN 2.0 ranges[85]
mustProgram resynchronisation jump width between 1 and min(4, PHASE_SEG1).calc: 1 <= SJW <= min(4, PHASE_SEG1)[86]
mustKeep CAN oscillator tolerance within 1.58 percent under the modified protocol.calc: clock tolerance vs bit timing[87]
guideThe Bosch protocol modification raises maximum oscillator tolerance from the existing protocol's 0.5% to 1.5%.review: controller protocol version vs clock tolerance[88]
mustKeep CAN bus length under 20 m at 1 Mbit/s, 100 m at 500 kbit/s, 250 m at 250 kbit/s, 500 m at 125 kbit/s, and 1000 m at 50 kbit/s.calc: bus length below the table value for the bit rate[76]
shouldFor NI-reported ISO 11898 cabling at 1 Mbps, use 40 m maximum total cable and 0.3 m maximum stub.calc: bus length <= 40 m and stub <= 0.3 m at 1 Mbps[80]
mustDo not apply the often quoted 40 m at 1 Mbit/s to optically isolated CAN controllers.calc: delay budget including isolators at the chosen bit rate[89]
mustTreat signal transit time as the main limit on CAN length, because arbitration needs signals to reach all nodes before the sample point.calc: round trip delay < sample point time[81]
mustUse CAN cable with a nominal specific line delay of 5 ns/m.calc: t_cable = L * 5 ns/m[82]
shouldAvoid CAN drop lines where possible; with Beckhoff Bus Coupler bit timing at 1 Mbit/s, keep each under 1 m and all drop lines under 5 m total.model-lint: drop line and total drop length vs bit rate[90]
mustWith passive multiport taps at 1 Mbit/s keep drop lines under 0.3 m and the trunk under 25 m.model-lint: multiport drop < 0.3 m and trunk < 25 m at 1 Mbit/s[91]
mustTerminate each end of a CAN bus with 120 ohm, even when the cable is very short.measure: two 120 ohm in parallel across CAN_H and CAN_L with power off[92]
shouldOnly devices at the two cable ends should have termination resistors.review: termination enable set only on the two end nodes[93]
shouldUse termination resistors able to dissipate at least 0.25 W.review: resistor power rating >= 0.25 W[94]
mustUse CAN cable with impedance between 108 and 132 ohm, 120 ohm nominal.review: cable data sheet impedance in range[95]
shouldUse CAN cable with a nominal length-related resistance of 70 milliohms per metre.calc: loop resistance from cable length and data sheet[96]
shouldAllow up to 64 CANopen devices only when all meet the CANopen specifications; the real maximum depends on electrical characteristics.calc: device count vs transceiver electrical data[97]
shouldRun a CAN reference conductor unless the network is physically small with one common power supply.review: harness carries CAN ground, or the exception is recorded[98]
shouldA CAN transmitter detects an acknowledgment error when it does not monitor a dominant bit in the ACK slot.measure: bench setup has a second active node[99]
guideBeckhoff's worst-case opto-coupler calculation gives 5 m at 1 Mbit/s, while stating 20 m can be reached in practice without difficulty.calc: bus length <= 5 m at 1 Mbit/s with opto-couplers, unless a timing calculation shows more[83]

RS-485

Wire it as a line, not a star or ring [100]. Terminate both ends, typically at 120 ohm [101]. Rate times length should not exceed 10^8, so a 50 m cable stays at or under 2 Mbit/s [102]. These come from a Wikipedia summary, because the TIA-485 standard is paid.

RS-485
LevelStatementCheckSource
shouldPlan for at least 32 unit loads on an RS-485 bus.calc: sum of device unit loads <= driver capability[75]
shouldGenerally RS-485 reaches 10 Mbit/s or, at lower speed, 1,200 m.calc: rate and length inside this envelope[103]
guideRule of thumb: bit rate times metres should not exceed 10^8, so a 50 m cable should not exceed 2 Mbit/s. The capture shows 108 because it drops the superscript; the worked example confirms 10^8.calc: bit/s * m <= 1e8[102]
shouldWire RS-485 as a line or bus, not a star or ring; these cause reflections or wrong termination impedance.model-lint: bus has one line topology[100]
mustTerminate both cable ends with a resistor equal to cable characteristic impedance, typically 120 ohm for twisted pair.measure: termination at both ends only[101]
mustKeep RS-485 receiver common-mode voltage within -7 V to +12 V; outside it corrupts signals and can damage devices.measure: ground offset and common-mode voltage at peak motor current[45]
shouldRS-485 does not specify bias resistors, and component suppliers no longer commonly recommend them.review: idle-bus behaviour against the transceiver data sheet[104]

EtherCAT

The cycle and jitter figures are the technology group's stated targets. Measure them on your own network [105].

EtherCAT
LevelStatementCheckSource
shouldEtherCAT 100BASE-TX links can use industrial Ethernet cable between nodes up to 100 m apart.model-lint: each copper link <= 100 m[77]
guideEtherCAT was designed for cycle times at or under 100 us and jitter at or under 1 us; treat these as its stated target, then measure on your own system.measure: cycle time and jitter on the actual network[105]
guideAn EtherCAT segment can address up to 65,535 devices.calc: node count <= 65535; timing budget per node separately[106]
shouldUse EtherCAT distributed clocks for synchronous axes; the first DC device serves as the reference clock.review: DC enabled for multi-axis sync; measure sync jitter[107]
guideExpect distributed clock jitter significantly below 1 us when correctly used.measure: sync signal jitter across axes[108]
guideEtherCAT's Working Counter lets the MainDevice monitor datagram consistency and withhold inconsistent data from the control application.review: firmware checks working counter each cycle and enters a safe state on mismatch[109]
shouldAdd cable redundancy by returning a cable from the last node to another port on the main device, where a cable break must not stop the segment.review: ring wiring for high availability robots[110]
shouldTake position measurements at exact equal intervals, since velocity is derived from them and small timing errors become velocity errors.measure: timestamp spacing of position samples[111]

Where the sources disagree

The database keeps both values. Do not average them.

Where the sources disagree
TopicOne sourceOther sourceWhat to doSources
Bundled 20 AWG currentFAA 9 A at 200 C ratingNASA 3.7 ANASA is for hard vacuum, FAA for air at high altitude. Keep both and pick by environment.[12], [13]
CAN length at 1 Mbit/sBeckhoff under 20 mISO 11898 via NI 40 mUse the shorter, unless your timing calculation supports more[76], [80]
CAN 40 m figureOften quotedBeckhoff: not for opto-isolated nodes; worst case 5 m, 20 m reachable in practiceRun the delay budget with the isolators[89], [83]
CAN stub at 1 Mbit/sISO via NI 0.3 mBeckhoff under 1 m each, under 5 m totalBeckhoff's rests on its bit timing settings[80], [90]
CAN oscillator toleranceModified protocol 1.58 percent; the other guideline says 1.5 percentExisting protocol 0.5 percentCheck which your controller implements[87], [88]
RS-485 termination valueTypically 120 ohmThe standard does not specify itMatch the cable impedance[101]
RS-485 biasingNot specified by RS-485Suppliers no longer commonly recommend itFollow the transceiver data sheet[104]

Sources

Each guideline in this chapter with its source, the date it was read and the exact words of the source. Level: must means breaking it causes failure or harm, should is good practice, guide is a rule of thumb.

  1. Check supply limits before motor selection, since battery and amplifier limits can set the available peak current. Level: must. maxonmotor.com 2026-11-08
  2. Check power supply requirements, such as maximum motor terminal voltage and current limits, during the first motor selection. Level: must. maxonmotor.com 2026-11-08
  3. Hold continuous load near 80 percent of source capacity when no monitoring is used; this is a rule of thumb, not a load analysis. 80 percent Level: guide. raanz.org.nz 2026-11-08“can exceed 80 percent output load limits of the”
  4. Size each wire for both voltage drop and overheating; both must be met. Level: must. raanz.org.nz 2026-11-08“(2) The size should be sufficient to pre-”
  5. Protect every power wire with a fuse or breaker located as close as possible to the source bus. Level: must. raanz.org.nz 2026-11-08“with circuit breakers or fuses located as close”
  6. Make the circuit protector open before anything downstream overheats or smokes. Level: must. raanz.org.nz 2026-11-08“breaker must always open before any compo-”
  7. A multi-cell battery must provide the required capacity and current within the application's voltage limits. Level: must. ntrs.nasa.gov 2026-11-08“adequate thermal management. The battery must provide both the capacity and current required”
  8. Lowering discharge temperature reduces Li-ion capacity and increases the slope of the discharge curve. Level: guide. ntrs.nasa.gov 2026-11-08“temperature will result in a reduction of capacity, as well as an increase in the slope of the”
  9. Count supply voltage, voltage drops and current limit when calculating available actuator torque. Level: should. standards.nasa.gov 2026-11-08“Supply voltage, voltage drops, current limit”
  10. Under FAA table conditions, bundled 24 AWG copper wire carries 2.5 A at 105 C rating, 4 A at 150 C, and 5 A at 200 C. 2.5 A Level: should. raanz.org.nz 2026-11-08“105 °C 150 °C 200 °C (See Note #2) circ.mils 24 2.5 4 5 28.40 475 22 3 5 6 16.20 755 20 4 7 9 9.88 1,216 18 6 9 12 6.23 1,900 16 7 11 14 4.81 2,426”
  11. NASA gives derated current for 24 AWG as 3.3 A single and 2.0 A bundled. 2.0 A Level: must. nepp.nasa.gov 2026-11-08“24 3.3 2.0”
  12. Under FAA table conditions, bundled 20 AWG copper wire carries 4 A at a 105 C conductor rating, 7 A at 150 C, and 9 A at 200 C. 9 A Level: should. raanz.org.nz 2026-11-08“105 °C 150 °C 200 °C (See Note #2) circ.mils 24 2.5 4 5 28.40 475 22 3 5 6 16.20 755 20 4 7 9 9.88 1,216 18 6 9 12 6.23 1,900 16 7 11 14 4.81 2,426”
  13. For 200 C wire at 70 C ambient or below in hard vacuum, NASA gives 20 AWG derated current as 6.5 A single and 3.7 A bundled. 3.7 A Level: must. nepp.nasa.gov 2026-11-08“20 6.5 3.7”
  14. Under FAA table conditions, bundled 16 AWG copper wire carries 7 A at 105 C rating, 11 A at 150 C, and 14 A at 200 C. 14 A Level: should. raanz.org.nz 2026-11-08“105 °C 150 °C 200 °C (See Note #2) circ.mils 24 2.5 4 5 28.40 475 22 3 5 6 16.20 755 20 4 7 9 9.88 1,216 18 6 9 12 6.23 1,900 16 7 11 14 4.81 2,426”
  15. NASA gives derated current for 16 AWG as 13.0 A single and 6.5 A bundled. 6.5 A Level: must. nepp.nasa.gov 2026-11-08“16 13.0 6.5”
  16. Under FAA table conditions, bundled 12 AWG copper wire carries 13 A, 19 A and 25 A in the three temperature rating columns. 25 A Level: should. raanz.org.nz 2026-11-08“12 13 19 25 2.02 5,874”
  17. NASA gives derated current for 12 AWG as 25.0 A single and 11.5 A bundled. 11.5 A Level: must. nepp.nasa.gov 2026-11-08“12 25.0 11.5”
  18. For sizes 24 through 10, FAA table ratings use 70 C ambient, 60,000-foot altitude, at least 33 bundled wires, and no more than 20 percent harness loading. 70 C Level: should. raanz.org.nz 2026-11-08“Note #1: Rating is for 70°C ambient, 33 or more wires in the bundle for sizes 24 through 10, and 9”
  19. Scale NASA derated wire current for lower rated insulation: 80 percent for 150 C wire and 70 percent for 135 C wire. 80 percent Level: must. nepp.nasa.gov 2026-11-08“a. For 150°C wire, use 80% of values shown in Table 4A. b. For 135°C wire, use 70% of values shown in Table 4A.”
  20. Do not exceed the current that heats a wire to its rated temperature at steady state. Level: should. raanz.org.nz 2026-11-08“of the wire should not be exceeded. Rated”
  21. Do not use wire with fewer than 19 strands. 19 strands Level: must. raanz.org.nz 2026-11-08“nation. Wire containing less than 19 strands”Review note: In the FAA source the 19-strand sentence sits in the paragraph about wire sizes smaller than #20; the record states it for all wire.
  22. Give wire under size 20 extra clamps and support, and keep it out of excessive vibration, repeated bending, or frequent disconnection. Level: should. raanz.org.nz 2026-11-08“desirable to use wire sizes smaller than #20,”
  23. Keep wire-group bend radius at least 10 times the largest wire or cable diameter, except supported terminal breakouts may use 3 times. 10 OD Level: should. raanz.org.nz 2026-11-08“10 times the outside diameter of the largest”
  24. FAA allowable drop bus to load is 0.5 V continuous and 1 V intermittent at 14 V, and 1 V and 2 V at 28 V. 0.5 V Level: should. raanz.org.nz 2026-11-08“14 0.5 1 28 1 2”
  25. Keep source-to-main-bus drop within 2 percent of regulated voltage at generator rated current or battery five-minute discharge rate. 2 percent Level: should. raanz.org.nz 2026-11-08“exceed 2 percent of the regulated voltage when”
  26. Include wire harness flex forces and long-term set as a resisting torque. Level: should. standards.nasa.gov 2026-11-08“Wire harness loads (flex forces and long-term set)”
  27. Route cables so that they cannot snag during motion. Level: should. docs.nvidia.com 2026-11-08
  28. Size wire to carry continuous current above the protector rating, including its time-current curve. Level: must. raanz.org.nz 2026-11-08“continuous current in excess of the circuit”
  29. Derate a switch nominal rating by factor 3 for 28 VDC motor loads. 3 Level: should. raanz.org.nz 2026-11-08“28 VDC Motor 3”
  30. Derate a switch nominal rating by factor 2 for 12 VDC motor loads. 2 Level: should. raanz.org.nz 2026-11-08“12 VDC Motor 2”
  31. Aircraft warning lights can be triggered when battery bus voltage falls below 13 V on a 14 V system or 26 V on a 28 V system. 13 V Level: guide. raanz.org.nz 2026-11-08“bus voltage drops below 13 volts on a 14-volt quantity within the rated capacity of the re- system or 26 volts on a 28-volt system.”
  32. Keep MOSFET gate-source voltage at no more than 0.60 of rating. 0.6 Level: should. nepp.nasa.gov 2026-11-08“Power MOSFETs Gate to Source Voltage 0.60”
  33. Keep MOSFET source-drain voltage, including worst-case transients, at no more than 0.75 of rating. 0.75 Level: should. nepp.nasa.gov 2026-11-08“Source to Drain Voltage 0.75”
  34. Do not exceed 125 C power MOSFET junction temperature, or 40 C below the maker's maximum, whichever is lower. 125 C Level: should. nepp.nasa.gov 2026-11-08“2/ Do not exceed Tj = 125 °C or 40 °C below the manufacturer's maximum rating, whichever is lower or less.”
  35. Derate power MOSFET junction temperature by a factor of 0.80. 0.8 Level: should. nepp.nasa.gov 2026-11-08“Junction Temperature 2/ 0.80”
  36. Derate connector working voltage to the lower of 25 percent of its dielectric test voltage and 75 percent of its rated working voltage. 25 percent Level: should. nepp.nasa.gov 2026-11-08“25% of the connector Dielectric Withstanding test Voltage (at sea level, unconditioned) - or - Operating Voltage 75% of the connector rated operating (working)”
  37. Derate connector temperature to rated maximum minus 25 C. 25 C Level: should. nepp.nasa.gov 2026-11-08“Rated maximum temperature, less 25°C”
  38. Limit contact current to the Table 4A wire derating value for the conductor size used; for printed-circuit connectors, derate by contact size as bundled wire, so a size 20 contact is derated like 20 AWG in a bundle. Level: should. nepp.nasa.gov 2026-11-08“Example, as a minimum, a size 20 contact shall be derated the same as a 20 AWG wire used in a bundled cable assembly.”
  39. Give each interface circuit a dedicated return wire close to its outgoing wire. 100 percent Level: should. standards.nasa.gov 2026-11-08“interface circuit will have 100 percent of its current (over all frequencies) return on a dedicated”
  40. Avoid shared return wires between circuits; this may be tolerable within one system component that provides its own box-to-box wiring. Level: should. standards.nasa.gov 2026-11-08“shown only to emphasize that it should not be done. Shared return wires cause common”
  41. Keep a ground wire shorter than one twentieth of a wavelength. Level: guide. standards.nasa.gov 2026-11-08“lengths are better (a ground wire should be shorter than one twentieth of a wavelength).”
  42. Provide electrical bonding and ground paths between moving and stationary parts to meet electromagnetic requirements. Level: must. standards.nasa.gov 2026-11-08“[DDMR 22] Mechanisms shall include electrical bonding and ground paths between moving and”
  43. For NASA mechanisms, bearings shall not carry electrical current; provide other current paths and bonding/ground paths between moving and stationary parts. Level: must. standards.nasa.gov 2026-11-08“[DDMR 20] Bearings shall not be used to carry electrical current.”
  44. Do not carry electrical current through gears. Level: must. standards.nasa.gov 2026-11-08“[DDMR 21] Gears shall not be used to carry electrical current.”
  45. Keep RS-485 receiver common-mode voltage within -7 V to +12 V; outside it corrupts signals and can damage devices. 12 V Level: must. en.wikipedia.org 2026-11-08“The allowable common-mode voltage is in the range −7 V to +12 V, i.e., ±7 V on top of the 0-5 V signal range.”
  46. Charge and discharge rates are commonly expressed as multiples of C rate, the current that discharges the battery to cutoff in one hour. Level: guide. ntrs.nasa.gov 2026-11-08“discharge the battery to the cutoff voltage in one hour.”
  47. Estimate sag from cell internal resistance: it ranges from 9 to 120 milliohm on small 1 to 3 Ah Li-ion cells. 120 mohm Level: should. ntrs.nasa.gov 2026-11-08“resistance for the Li-Ion cells varies from 9 to 120 mΩ for small (1 to 3 Ah) cells to about 0.8”
  48. A cell discharged at a high rate to cutoff still has additional capacity above that cutoff if discharge continues at a lower rate. Level: guide. ntrs.nasa.gov 2026-11-08“that has been discharged at a higher current rate to a specific cutoff voltage still has additional”
  49. Most Li-ion cells work best between 20 and 40 C; keep the pack in the cell's stated temperature range. 40 C Level: should. ntrs.nasa.gov 2026-11-08“between 20 and 40°C, although electrolytes have been developed by JPL for their rover missions”
  50. Remember that high rate discharge can raise cells far above ambient. Level: should. ntrs.nasa.gov 2026-11-08“battery may heat up to temperatures far above ambient, and thus show the same effects of”
  51. Do not discharge a Li-ion cell below 2.5 V; typical equipment stops at 3.0 V per cell. 2.5 V Level: should. ntrs.nasa.gov 2026-11-08“on the load used, but the end voltage during discharge should not go below 2.5 V. Typical end of discharge voltages for the batteries in different equipment has been 3.0 V/cell.”Review note: NASA RP says end voltage 'should not' go below 2.5 V and depends on load; advisory, not a must.
  52. For typical Li-ion cells with layered cathodes, constant-current charge to 3.9–4.2 V depending on cathode and manufacturer recommendations. 4.2 V Level: should. ntrs.nasa.gov 2026-11-08“charge to a voltage of 3.9 V to 4.2 V (depending on the metal oxide cathode and manufacturer's”
  53. For typical layered-cathode Li-ion cells, hold constant voltage until current falls to approximately C/50 or C/100, as the manufacturer specifies. 50 Level: should. ntrs.nasa.gov 2026-11-08“C/50 or C/100 (this can vary according to the manufacturer).”
  54. After removing outliers, require the lot's ±3-sigma OCV range to be less than 1% of the mean. 1 percent Level: should. ntrs.nasa.gov 2026-11-08“(±3-sigma range/mean) should not exceed the following: 1. OCV (<1%) 2. Mass (<2%) 3. Capacity (<5%)”
  55. After removing outliers, require ±3-sigma capacity range below 5% and mass range below 2% of their means. 5 percent Level: should. ntrs.nasa.gov 2026-11-08“(±3-sigma range/mean) should not exceed the following: 1. OCV (<1%) 2. Mass (<2%) 3. Capacity (<5%)”
  56. After removing outliers, require the lot's ±3-sigma DC and AC resistance ranges to be less than 15% of their means. 15 percent Level: should. ntrs.nasa.gov 2026-11-08“4. DC and AC resistance (<15%)”
  57. Acceptance testing should include at least 10 charge/discharge cycles in total, counting vendor, screening, subassembly, and completed-assembly cycles. 10 cycles Level: should. ntrs.nasa.gov 2026-11-08“Acceptance testing should include a minimum of 10 charge/discharge cycles to”
  58. Use only lithium cell or pack types proven to meet UN Manual of Tests and Criteria 38.3 for transport. 38.3 Level: must. law.cornell.edu 2026-11-08“(1) Each lithium cell or battery must be of the type proven to meet the criteria in part III, sub-section 38.3 of the UN Manual of Tests and Criteria”
  59. For 49 CFR 173.185(c), lithium-ion limits are generally 20 Wh per cell and 100 Wh per battery, with a marked highway/rail-only exception of 60 Wh and 300 Wh. 100 Wh Level: must. law.cornell.edu 2026-11-08“(i) The Watt-hour (Wh) rating may not exceed 20 Wh for a lithium ion cell or 100 Wh for a lithium ion battery.”
  60. Do not charge a Li-ion cell above the vendor's recommended voltage; overcharge can cause internal shorts, venting and flames. Level: must. ntrs.nasa.gov 2026-11-08“that can result in venting with flames. Li-Ion cells must not be charged to a voltage greater than”
  61. Use a dedicated Li-ion charger or a universal smart charger that recognizes the battery chemistry. Final testing should treat battery and charger as one unit. Level: must. ntrs.nasa.gov 2026-11-08“Final testing should treat the battery and charger as a unit or system.”
  62. Fit charge control to prevent overcharge, which can cause venting or rupture. Level: must. ntrs.nasa.gov 2026-11-08“can cause venting or rupture. The manufacturers' recommendations for maximum voltage”
  63. In a series string control voltage so the lowest cell is not driven into reversal, which can cause venting or rupture. Level: must. ntrs.nasa.gov 2026-11-08“being driven into voltage reversal possibly resulting in cell venting or rupture.”
  64. For NASA crewed spacecraft, the battery/charger design shall maintain required failure tolerance against overcharge and over-discharge. Level: must. ntrs.nasa.gov 2026-11-08“a. The battery/charger design shall maintain required failure tolerance against”
  65. Keep operation inside limits recommended by the maker or found in qualification testing. Level: must. ntrs.nasa.gov 2026-11-08“b. Operational procedures shall ensure that the battery is not operated outside”
  66. For NASA batteries above 80 Wh using cells above 80 Wh/kg with catastrophic failure modes, evaluate worst-case single-cell thermal runaway severity and cell-to-cell propagation in the intended application and environment. Level: should. ntrs.nasa.gov 2026-11-08“severity of a worst-case single-cell thermal runaway event and the propensity of”
  67. Do not pot cells in a way that blocks their vents. Level: must. ntrs.nasa.gov 2026-11-08“of potting materials that would prevent them from venting safely.”
  68. Except for cells or batteries meeting 49 CFR 173.185(c), a lithium battery with cells or series strings in parallel must have a means to prevent dangerous reverse current, such as diodes or fuses. Level: must. law.cornell.edu 2026-11-08“(iii) Be equipped with a means of preventing dangerous reverse current flow (e.g., diodes or fuses) if a battery contains cells, or a series of cells that are connected in parallel.”
  69. Except for cells or batteries meeting 49 CFR 173.185(c), each lithium cell or battery must have a means of preventing external short circuits. Level: must. law.cornell.edu 2026-11-08“(ii) Be equipped with means of preventing external short circuits; and”
  70. Address external shorts at pack level if cells lack current interrupt devices; fuses, breakers and thermal switches can be used. Level: must. ntrs.nasa.gov 2026-11-08“Interrupters may be fuses, circuit breakers, thermal”
  71. Do not rely on cell PTC devices in series or parallel/series strings, as they may not protect as they do in single cells. Level: should. ntrs.nasa.gov 2026-11-08“external short condition. However, when used in series strings or parallel/series designs, they”
  72. Find the maximum number of cells in series without a bypass diode by test. Level: should. ntrs.nasa.gov 2026-11-08“to prevent these failures. The maximum number of cells in series without a bypass diode”
  73. Anodize inner metal battery-case surfaces or coat them with non-electrically conductive, electrolyte-resistant paint to prevent electrolyte shorts. Level: should. ntrs.nasa.gov 2026-11-08“anodized finish or be coated with a non-electrically conductive, electrolyte-resistant paint. Cell”
  74. Cycling can unbalance cells; long-cycle-life or low-margin applications are more likely to require cell monitoring and end-of-charge or discharge control. Level: should. ntrs.nasa.gov 2026-11-08“margin, it is more likely that cell-level monitoring and end-of-charge or discharge control will be”
  75. Plan for at least 32 unit loads on an RS-485 bus. 32 Level: should. en.wikipedia.org 2026-11-08“Maximum devices At least 32 unit loads”
  76. Keep CAN bus length under 20 m at 1 Mbit/s, 100 m at 500 kbit/s, 250 m at 250 kbit/s, 500 m at 125 kbit/s, and 1000 m at 50 kbit/s. 20 m Level: must. infosys.beckhoff.com 2026-11-08
  77. EtherCAT 100BASE-TX links can use industrial Ethernet cable between nodes up to 100 m apart. 100 m Level: should. ethercat.org 2026-11-08
  78. Use short high-quality USB3 cables for depth cameras, preferably under 1 m, and active repeaters beyond 2 m. 1 m Level: should. dev.realsenseai.com 2026-11-09
  79. For stable communication at high baud rates, lower the USB latency setting. Level: should. github.com 2026-11-08
  80. For NI-reported ISO 11898 cabling at 1 Mbps, use 40 m maximum total cable and 0.3 m maximum stub. 40 m Level: should. ni.com 2026-11-08
  81. Treat signal transit time as the main limit on CAN length, because arbitration needs signals to reach all nodes before the sample point. Level: must. infosys.beckhoff.com 2026-11-08
  82. Use CAN cable with a nominal specific line delay of 5 ns/m. 5 ns/m Level: must. ni.com 2026-11-08
  83. Beckhoff's worst-case opto-coupler calculation gives 5 m at 1 Mbit/s, while stating 20 m can be reached in practice without difficulty. 5 m Level: guide. infosys.beckhoff.com 2026-11-08
  84. In CAN 2.0 bit-stuffed frame segments, a transmitter inserts a complementary bit after five consecutive identical bits. Level: guide. esd.cs.ucr.edu 2026-11-08
  85. CAN 2.0 defines SYNC_SEG as 1 time quantum and PROP_SEG and PHASE_SEG1 as programmable from 1 to 8 time quanta. 8 quanta Level: guide. esd.cs.ucr.edu 2026-11-08
  86. Program resynchronisation jump width between 1 and min(4, PHASE_SEG1). 4 Level: must. esd.cs.ucr.edu 2026-11-08
  87. Keep CAN oscillator tolerance within 1.58 percent under the modified protocol. 1.58 percent Level: must. esd.cs.ucr.edu 2026-11-08
  88. The Bosch protocol modification raises maximum oscillator tolerance from the existing protocol's 0.5% to 1.5%. 0.5 percent Level: guide. esd.cs.ucr.edu 2026-11-08
  89. Do not apply the often quoted 40 m at 1 Mbit/s to optically isolated CAN controllers. 40 m Level: must. infosys.beckhoff.com 2026-11-08
  90. Avoid CAN drop lines where possible; with Beckhoff Bus Coupler bit timing at 1 Mbit/s, keep each under 1 m and all drop lines under 5 m total. 1 m Level: should. infosys.beckhoff.com 2026-11-08
  91. With passive multiport taps at 1 Mbit/s keep drop lines under 0.3 m and the trunk under 25 m. 25 m Level: must. infosys.beckhoff.com 2026-11-08
  92. Terminate each end of a CAN bus with 120 ohm, even when the cable is very short. 120 ohm Level: must. infosys.beckhoff.com 2026-11-08
  93. Only devices at the two cable ends should have termination resistors. Level: should. ni.com 2026-11-08
  94. Use termination resistors able to dissipate at least 0.25 W. 0.25 W Level: should. ni.com 2026-11-08
  95. Use CAN cable with impedance between 108 and 132 ohm, 120 ohm nominal. 120 ohm Level: must. ni.com 2026-11-08
  96. Use CAN cable with a nominal length-related resistance of 70 milliohms per metre. 70 mohm/m Level: should. ni.com 2026-11-08
  97. Allow up to 64 CANopen devices only when all meet the CANopen specifications; the real maximum depends on electrical characteristics. 64 Level: should. ni.com 2026-11-08
  98. Run a CAN reference conductor unless the network is physically small with one common power supply. Level: should. infosys.beckhoff.com 2026-11-08
  99. A CAN transmitter detects an acknowledgment error when it does not monitor a dominant bit in the ACK slot. Level: should. esd.cs.ucr.edu 2026-11-08
  100. Wire RS-485 as a line or bus, not a star or ring; these cause reflections or wrong termination impedance. Level: should. en.wikipedia.org 2026-11-08“Star and ring topologies are not recommended because of signal reflections or excessively low or high termination impedance.”
  101. Terminate both cable ends with a resistor equal to cable characteristic impedance, typically 120 ohm for twisted pair. 120 ohm Level: must. en.wikipedia.org 2026-11-08“The value of each termination resistor should be equal to the cable characteristic impedance (typically, 120 ohms for twisted pai”
  102. Rule of thumb: bit rate times metres should not exceed 10^8, so a 50 m cable should not exceed 2 Mbit/s. The capture shows 108 because it drops the superscript; the worked example confirms 10^8. 50 Level: guide. en.wikipedia.org 2026-11-08“the speed in bit/s multiplied by the length in meters should not exceed 108. Thus a 50-meter cable should not signal faster than 2 Mbit/s.”
  103. Generally RS-485 reaches 10 Mbit/s or, at lower speed, 1,200 m. 1200 m Level: should. en.wikipedia.org 2026-11-08“can be used with data rates up to 10 Mbit/s[a] or, at lower speeds, distances up to 1,200 m (4,000 ft).”
  104. RS-485 does not specify bias resistors, and component suppliers no longer commonly recommend them. Level: should. en.wikipedia.org 2026-11-08“However, bias resistors are no longer commonly recommended by component suppliers.”
  105. EtherCAT was designed for cycle times at or under 100 us and jitter at or under 1 us; treat these as its stated target, then measure on your own system. 100 us Level: guide. ethercat.org 2026-11-08
  106. An EtherCAT segment can address up to 65,535 devices. 65535 Level: guide. ethercat.org 2026-11-08
  107. Use EtherCAT distributed clocks for synchronous axes; the first DC device serves as the reference clock. Level: should. ethercat.org 2026-11-08
  108. Expect distributed clock jitter significantly below 1 us when correctly used. 1 us Level: guide. ethercat.org 2026-11-08
  109. EtherCAT's Working Counter lets the MainDevice monitor datagram consistency and withhold inconsistent data from the control application. Level: guide. ethercat.org 2026-11-08
  110. Add cable redundancy by returning a cable from the last node to another port on the main device, where a cable break must not stop the segment. Level: should. ethercat.org 2026-11-08
  111. Take position measurements at exact equal intervals, since velocity is derived from them and small timing errors become velocity errors. Level: should. ethercat.org 2026-11-08